For owners & general contractors

Construction fire safety plans, prepared and seen through their approval.

We write your NFPA 241 or IFC Chapter 33 plan, submit it to your fire department, and handle their comments until it's approved.

MA · NH · RI · CT · ME · VT · NY · FIXED FEE

Tower crane over a podium deck, with wood-frame walls going up and lumber staged across the slab
On site · Wood-frame over podium

01 — Services

Everything it takes to get your plan approved

We prepare the plan, submit it, and stay with it until your Authority Having Jurisdiction signs off.

Construction fire safety plan

A complete fire safety plan for your site, NFPA 241 or IFC Chapter 33, written to your fire department’s requirements.

Fire department submission

We file the plan with your Authority Having Jurisdiction and handle the follow-up, so your team can stay on the job.

Comments and revisions

When the fire department comes back with comments, we respond and resubmit until the plan is approved.

Every plan covers

FP-001

Site Access & Fire Routes

Fire department access roads, gate locations, and staging areas

FP-002

Water Supply

Hydrant locations, standpipe connections, and flow rate documentation

FP-003

Fire Protection Systems

Sprinkler, alarm, standpipe, and detection system status tracking

FP-004

Hot Work Program

Permit procedures, designated areas, and fire watch requirements

FP-005

Combustible Management

Storage locations, waste removal schedules, and heating equipment

FP-006

Emergency Procedures

Evacuation routes, assembly points, and emergency contact chains

FP-007

Inspection Schedules

Daily and weekly inspection checklists

FP-008

Responsible Parties

Fire prevention manager, safety director, and contractor assignments

In the field

Emergency egress plan taped below a Stair 3 Ground Level sign on a concrete column

FP-006 · Emergency Procedures

Egress plans posted at every stair, so crews know the way out on every level.

Wood-frame corridor with temporary sprinkler piping overhead and a fire extinguisher station

FP-003 · Fire Protection Systems

Sprinkler piping and extinguishers in place as the building closes in.

Standpipe riser with a hose valve and control valve in a wood-frame stair shaft at Stair 3, Level 3

FP-002 · Water Supply

Standpipe risers extended as each floor goes up, with a hose valve ready at every stair landing.

02 — How it works

Send one message. We handle the rest.

  1. 01

    Tell us about your project

    Send a message with the project location, building type, and timeline. We’ll reply by email with a fixed-fee quote and next steps.

  2. 02

    We prepare your plan

    We review your project against your state’s fire code and your fire department’s requirements and write the plan. You’ll get an email when it’s ready.

  3. 03

    We submit it

    We file the plan directly with your fire department and handle their comments until it’s approved.

03 — Service area

New England and New York

We prepare and submit plans for projects in seven states.

  • MAMassachusettsNFPA 241
  • NHNew HampshireNFPA 241
  • RIRhode IslandNFPA 241
  • CTConnecticutNFPA 241
  • MEMaineNFPA 241
  • VTVermontNFPA 241
  • NYNew YorkIFC Chapter 33
  • NYCNew York CityNYC FC Chapter 33

Project somewhere else? Email us and we'll let you know.

CTMEMANHNYVTRI

04 — Pricing

A fixed fee, not an hourly bill.

We quote a fixed fee up front, before any work starts. No hourly billing and no surprise invoices.

Every plan includes

  • Plan prepared under a certified building official
  • Submission to your fire department
  • Responses to fire department comments
  • Revisions until approved
  • Email updates at every stage
Contact us

05 — Questions

Common questions

What is an NFPA 241 fire safety plan?
NFPA 241 is the standard for safeguarding construction, alteration, and demolition operations. It requires a written fire safety plan covering site access, water supply, fire protection systems, hot work, combustible management, emergency procedures, inspection schedules, and responsible parties.
What about New York?
New York follows IFC Chapter 33 instead of NFPA 241, and New York City has its own Fire Code Chapter 33. The plans cover the same ground: site access, water supply, hot work, and emergency procedures. We write to whichever code your project falls under.
Which states do you work in?
We prepare and submit plans for projects in Massachusetts, New Hampshire, Rhode Island, Connecticut, Maine, Vermont, and New York.
How is pricing set?
Each plan is a fixed fee — no hourly billing. We quote a fixed fee up front, before any work starts.
Do you deal with the fire department?
Yes. We submit the plan directly to your fire department and respond to their comments until the plan is approved.

Get your fire safety plan prepared and approved.

Tell us about your project. We'll take it from there — preparation, submission, and revisions until it's approved.

Contact us